Hydranautics Hydracap Max 40, Max40 UF Membrane Equivalent (TIPS)

Product Details
Customization: Available
Membrane Type: Hollow
Type: UF
Still deciding? Get samples of US$ 930.21/Piece
Request Sample
Manufacturer/Factory, Trading Company
Gold Member Since 2023

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Plant Area
10000 square meters
Management System Certification
ISO 9001
  • Hydranautics Hydracap Max 40, Max40 UF Membrane Equivalent (TIPS)
  • Hydranautics Hydracap Max 40, Max40 UF Membrane Equivalent (TIPS)
  • Hydranautics Hydracap Max 40, Max40 UF Membrane Equivalent (TIPS)
  • Hydranautics Hydracap Max 40, Max40 UF Membrane Equivalent (TIPS)
  • Hydranautics Hydracap Max 40, Max40 UF Membrane Equivalent (TIPS)
  • Hydranautics Hydracap Max 40, Max40 UF Membrane Equivalent (TIPS)
Find Similar Products
  • Overview
  • Product Description
  • Certifications
  • Packaging & Shipping
  • Our Advantages
  • Inquiry Handling Process
  • Order Handling Process
  • After Sales Service
  • FAQ
Overview

Basic Info.

Model NO.
TFMAXP52
Membrane Material
PVDF
Pore Size
0.08 Um
Fiber ID/Od
0.6 mm/1.2 mm
Flow Direction
Outside-in
Membrane Area
52 M2
Diameter
250 mm
Length
1364.9 mm
Connection
DN 50 Coupling
Equivalent
Hydranautics Hydracap Max 40
Transport Package
Paper Carton
Specification
152*48*48 cm
Trademark
Tanal
Origin
China
HS Code
8421999090
Production Capacity
50000 Pieces/Year

Product Description

Product Description

General Information

TFMAXP52 is manufactured as the direct equivalent, replacement, alternative, retrofit and analogue to replace Hydranautics HYDRAcap MAX 40 (MAX40) UF membrane module.
Hydranautics HYDRAcap MAX 40 equivalent ultrafiltration (UF) membrane module TFMAXP52
 are pressurized modules, which are designed and manufactured for the filtration of surface water, potable water, seawater and industrial wastewater. These UF modules are made of new generation TIPS (thermally induced phase separation) PVDF hollow fiber membrane with high tensile strength and fouling resistance.TaFlux TaCap Max Pro series ultrafiltration (UF) membrane modules are pressurized modules, which are designed and manufactured for the filtration of surface water, potable water, seawater and industrial wastewater. These UF modules are made of new generation TIPS (thermally induced phase separation) PVDF hollow fiber membrane with high tensile strength and fouling resistance.
TFMAXP52 UF modules are applied in flexible UF systems, providing high-quality filtrate by removing suspended solids, colloids, pyrogens, bacteria, viruses and other impurities to protect downstream processes such as NF and RO.

Features

  • Outside-to-inside flow direction
  • New generation PVDF hollow fiber
  • Uniform pore size of 0.08 μm
  • Typical filtrate turbidity ≤ 0.1 NTU
  • Bacteria removal ≥ 4 log

Advantages

  • Extra high tensile strength for longer service life
  • High tolerance for feed water
  • High-quality filtrate
  • Less energy needed for high flux
  • Longer service life by high resistance
  • Economical equivalent module for direct replacement of Hydranautics HYDRAcap MAX 40

Applications

  • Surface water
  • Potable water
  • Beverage clarification
  • Industrial process water
  • Reclaimed water reuse
  • Industrial wastewater
  • Pre-treatment of seawater desalination

Module Dimensions

Hydranautics Hydracap Max 40, Max40 UF Membrane Equivalent (TIPS)
Model L
(mm/in)
L1
(mm/in)
L2
(mm/in)
D
(mm/in)
D1
(mm/in)
W
(mm/in)
Connection port Air inlet
TFMAXP52 1364.9/53.74 1257.3/49.5 1135.5/44.7 250/9.84 290/11.42 172/6.8 DN50 3/8" FNPT
Specifications
Specifications Parameters
Model TFMAXP52
Effective membrane area (m²/ft²) 52/560
Filtrate flow rate m3/h (gpm) 1.7 - 6.2 (7.5 - 27.3)
Dry weight (KG/lbs) 41/90
Wet weight filled with water (KG/lbs) 73/161
Membrane material PVDF (Polyvinylidene Fluoride), (TIPS)
Fiber ID/OD 0.6/1.2 mm (0.024/0.047 inch)
Flow direction Outside-in
Pore size 0.08 μm
Housing material UPVC
Potting material Epoxy resin
Operating and Cleaning Limits
Type of operation Dead-end flow or cross flow
Typical flux (25°C) 34 - 120 L/m2·h (20 - 71 gfd)
Temperature 1 - 40°C (34 - 104°F)
Maximum feed pressure (20°C) 5 bar (73 psi)
Maximum feed pressure (40°C) 3 bar (44 psi)
Maximum trans-membrane pressure 2 bar (30 psi)
Maximum air scour feed pressure 2.5 bar (36 psi)
Air scour flow 12.3 - 15.4 Nm3/h (7.3 - 9.1 acfm)
Air scour duration  2 - 4 minutes
Air scour frequency Once every 20 - 60 minutes
pH-Continuous operation @25°C 2 - 11
pH-Cleaning @25°C 1 - 13
Maintenance cleaning frequency 1 - 3 times per day
Maintenance clean duration 20 - 30 minutes
Disinfection chemicals NaClO, ClO2 or NH2Cl
Cleaning chemicals NaOH, HCl, H2SO4 or citric acid
Instantaneous chlorine tolerance 5,000 ppm
Maximum chlorine exposure 750,000 ppm-hrs
Maximum feed TSS 100 ppm
Maximum feed turbidity 300 NTU
Maximum feed particle size 300 µm
Filtrate SDI15 ≤ 2.5
Filtrate turbidity ≤ 0.1 NTU
Certifications

ISO 9001:2015 Quality Management Systems Certificate
TÜV Audit Certificate
Export License
Certificate of Origin

Packaging & Shipping

Hydranautics Hydracap Max 40, Max40 UF Membrane Equivalent (TIPS)Hydranautics Hydracap Max 40, Max40 UF Membrane Equivalent (TIPS)Hydranautics Hydracap Max 40, Max40 UF Membrane Equivalent (TIPS)Hydranautics Hydracap Max 40, Max40 UF Membrane Equivalent (TIPS)Hydranautics Hydracap Max 40, Max40 UF Membrane Equivalent (TIPS)

Our Advantages

1. Customer-centric company culture
2. Efficient and flexible organizational system
3. 20+ years experience in membrane research, development and manufacturing
4. Better cost-effectiveness

Inquiry Handling Process

Hydranautics Hydracap Max 40, Max40 UF Membrane Equivalent (TIPS)

Order Handling Process

Hydranautics Hydracap Max 40, Max40 UF Membrane Equivalent (TIPS)

After Sales Service

1. Warranty granted.
2. Remote technical training, guidance and support.
3. On-site technical support for training, installation, commissioning, operation and trouble shooting.
4. Free replacement in warranty period.
Feedback Handling Process as below:
Hydranautics Hydracap Max 40, Max40 UF Membrane Equivalent (TIPS)

FAQ

Hydranautics Hydracap Max 40, Max40 UF Membrane Equivalent (TIPS)
Picking up the phone and having the plant manager yelling at you about undelivered membranes and filters?
Your customers are complaining to you about the high costs of existing membranes and filters?
Feel frustrated in prices when you are bidding?

Send your inquiry to us and get a quote for your project now!

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier